지열히트펌프를 사용하는 유리온실 육묘장의 전기에너지 사용량 분석

류연수, 박미란, 김진욱 et al. · 한국태양에너지학회 춘계학술발표회 논문집 · 2015

Horticultural greenhouse has increased steadily due to aggressive policies of government since 1990 in Korea. It has areas of 48,476 ha, about 33% of them is heating facilities. Heating costs are investigated in 30∼40% of operating costs in case of heating using oil boiler. The government has supported geothermal heat pump system in order to reduce heating costs of farmers since 2009. An investigation shows that farm using geothermal heat pump has 165 places with 92,856 kW. In addition, the supply of geothermal heat pump system is growing in livestock and fishery. However, although heating costs are cheap compared to oil boiler, geothermal heat pump system uses up a lot of electricity. In this study, we analyzed scale of equipment and annual electricity usage about nursery operated steadily by geothermal heat pump system for heating and cooling of greenhouse. In addition, we compared the nursery of 3 places (Gongju-si in Chungcheongnam-do, Chungju-si in Chungcheongbuk-do, Damyang-gun in Jeollanam-do) that has different outdoor temperature. 1) The design temperature based on observed temperature for 30 years has -17.2℃ (Chungju nursery), -12.4℃ (Gongju nursery), and ?8.5℃ (Damyang nursery) respectively. The scale of heat pump equipment per area has 0.1 kW/m2, 0.09 kW/m2, and 0.08 kW/m2 respectively. This shows that the lower outdoor temperature, the larger scale of equipment.

Cited by 0 works.

Authors