초고층 주거복합 건물의 미진동 계측 및 구조물 식별

유은종, 김승남, 김지영 et al. · 한국지진공학회 춘계학술발표회 논문집 · 2008

Ambient vibration measurement and system identification of a 42 story residential building was performed. Using 24 channel force-balance type accelerometers with three sensors at the 42th floor as reference, accelerations at 66 points from the 3rd floor to the 42th floor were measured from seven setups in total. The frequency domain decomposition method and stochastic subspace identification method were adopted to identify modal properties of the structure from the output-only measurement. Excellent agreement of the natural frequencies and mode shapes were observed between the results from the two method. Agreement of the modal damping ratios were not as good as the other modal properties.

Cited by 0 works.