자동차용 난방장치의 공기열원 및 수열원 이용방식에 따른 성능특성 비교
송뢰, 고광수, 박윤철 · 한국태양에너지학회 춘계학술발표회 논문집 · 2015
In this experiment, in order to evaluate vehicle with air mixer performance of heating, the original heating Heat pump evaporation machine for plate type Heat exchanger in the system, through the flow of refrigerant in the system and stack ways of using waste Heat can be directly Heat exchange water Heat source system structure. Indoor air conditions dry bulb temperature is 20 ℃, wet bulb temperature 15 ℃, the outdoor air condition is dry bulb temperature 7 ℃, under the condition of wet bulb temperature 6 ℃, by changing the number of EEV (25%, 50%, 50%, 25%), compressor rotation number (1200 RPM, 1800 RPM, 1200 RPM). The same experiment conditions, the higher the compressor rotation number, the more power consumption. Air heat source utilization way, the rotation of the compressor of 1200 RPM and number of EEV 25%, COPh is the highest of 2.03.The water heat source utilization way, the rotation of the compressor number 1200 RPM, the number of EEV 75%, stack waste heat temperature of 50 ℃, COPh is the highest of 9.42.