Возможности МР-динамического контрастирования в дифференциальной диагностике первичных и вторичных опухолей головного мозга
E. А. Nechipay, Михаил Борисович Долгушин, Igor Pronin et al. · 2015
Aim: the article is devoted to determine the capabilities of T1-dynamic contrast enhanced magnetic resonance imaging (DCE-MRI) in differentiation diagnosis primary and secondary brain tumors. Materials and methods. The analysis was based on data generated from MRI examinations using a T1-DCE protocol of 74 patients with intracerebral tumors: gliomas - 24 (32.4%) cases (glioblastoma - 17, astrocytoma - 5 and oligodendroglioma - 2), meningioma - 23 (31.1%) and metastases - 27 (36.5%) cases (melanoma - 8, breast cancer - 7 and lung cancer - 12). MRI was performed on 3,0-T scanner (Skyra, Siemens AG, Erlangen Germany) and included following sequences: a) routine sequences in axial direction before contrast agent injection (T1-SE, T2-SE, T2-FLAIR, DWI), b) T1-Vibe with two different flip angles and DCE-protocol, c) T1-VIBE in axial direction after contrast injection with 3D-reconstruction. Results. The highest average K trans and V e were observed in meningiomas (0.097 ± 0.019 min -1 and 0.151 ± 0.017), the lowest in gliomas Grade I-II (0.022 ± 0.001 min -1 and 0.029 ± 0.003). The highest average were in melanoma mts (1.14 ± 0.331 min -1 ) and lowest - in breast cancer mts (0.063 ± 0.193 min -1 ). Conclusion. DCE MRI - potentially perspective and demanding further studying method allowing to assume possibility of carrying out effective differential diagnostics of various brain tumors by a cumulative assessment of the pharmacokinetic parameters providing valuable information on hemodynamic and proliferative properties of tumor tissue.