공동주택 강철제 방화문의 기밀성능과 결로방지성능과의 상관관계 비교
여한승, 이길용, 서보열 et al. · 대한설비공학회 2017년도 하계학술발표대회 · 2017
Recently, there are main issues about condensation prevention performance of steel fire doors in the Apartment house. The purpose of this paper is to find the correlation between air tightness performance(q:Air flow rate) and condensation prevention performance(TDR:Temperature Difference Ratio) of steel fire doors to contribute to the development of multi-performance steel fire doors. The results obtained show that the coefficient of determination(R2) between Air flow rate and maximum TDR at the door slab and the door frame is low relations. Therefore, it is found that there are low correlations between air tightness performance and condensation prevention performance, because the main factors affecting air tightness performance and condensation prevention performance are different.
Cited by 0 works.