논문 : 대전지역 지하상가의 대기오염도에 관한 조사연구

양천회, 류완호, 장철현 et al. · 1994

In order to assess the level of atmospheric pollution and to contribute the health improvement of residents in Taejon city, the authors were measured the concentration of air pollutants(CO, SO₂, NO₂, TSP, Pb, Cd, Cr) at three places of the control road in Taejon. The investigative research performed bimonthly from May 1993 to September 1993, and the places were the underground shopping stores of Taejon station, Dongyang department store and provincial goverment areas. The results of statistical analysis are as followings. ① CO : 0.569∼0.966 ppm ② SO₂: 0.084∼0.170ppm ③ NO₂: 0.0045∼0.022ppm ④ TSP : 249∼299㎍/㎥ ⑤ Pb : 0.366∼1.157㎍/㎥ ⑥ Cd : 0.016∼0.025㎍/㎥ The mean concentration of SO₂ in Dongyang department store area was 0.17ppm, and it exceeded the ambient air quality standard by 0.02ppm. The concentration of TSP was higher than a standing rule of public hygiene, and it was very near to a standing rule of environmental preservation.

Cited by 0 works.