Most of the horticultural greenhouses have been operating a hot-water boiler or hot blast heater using tax exemption oil for agriculture and fishery. Now a days, the government has activated the spread of eco-friendly geothermal heat pump system. The geothermal heat pump system has disadvantage of initial equipment cost, whereas, it has advantage of inexpensive electricity bill and being able to operate the cooling in summer season. Because of these advantage, this system has been extended to various agriculture sector such as aquafarm and livestock. In this study, we analyzed a study on the effect of solar radiation on system operation through comparing power consumption of geothermal heat pump system according to solar radiation in a glass greenhouse. 1) A target area for research is nursery farm located in Gongju-si, Chungcheongnam-do. Type and area of the greenhouse is wide span and 5,358m2 respectively. The geothermal heat pump system is water to water system, it has two heat pump with 171.2 kW and one heat pump with 145.4 kW. We analyzed solar radiation, outdoor air temperature and power consumption of geothermal heat pump system from December 2011 to November 2012. Monthly average radiation was the highest in May(21.49 MJ/m2), whereas, it was the lowest in December(8.00 MJ/m2) for one year. Monthly mean temperature was the highest in August(27.73℃), whereas, it was the lowest in January(-2.55℃). In addition, monthly average power consumption was the highest in January(2,277.14 kWh), whereas, it was the lowest in September(603.61 kWh).