편심압축을 받는 고강도 콘크리트충전강관 기둥에서 전단연결재 효과
정경수, 최인락, 정미영 et al. · 한국강구조학회 학술발표대회 논문집 · 2011
Experimental data for square CFT columns made from high-strength steel (Fy>550MPa) and high strength concrete (fck>100MPa) under loading is lacking. Therefore, the behaviour of square concrete-filled steel tube members made from high-strength materials was investigated experimentally. Four full scale CFT specimens were tested cyclically. The primary test parameter was material strength and shear connector. The effect of material strength and shear connector on structural behavior of high-strength CFT members was studied.
Cited by 0 works.