양방향 펌프의 유동 해석을 통한 펌프 케이싱의 최적설계

김동휘, 노유정, 임오강 et al. · 2018

A two-way pump can reduce costs by draining and circulating water out and into the drum of the washing machine using a single motor whereas a conventional one-way pump uses two motors for doing the same function. However, when the water is drained through the drainage outlet in the two-way pump casing, a backward or inhalation flow occurs and the water flows to the circulation outlet. Likewise, when the water is circulated, the backward flow or inhalation makes the water flow to the drainage outlet. In this study, design optimization of the two-way pump casing is performed to maximize its performance while improving backward flow and inhalation occurring inside of the pump casing. For this, design variables of the pump casing that mainly affect the performance of the pump such as flow rate and torque of the motor were selected through the analysis of mean. Using response surface models for the performances, the ratio of the flow rate to the torque was maximized with satisfying the constraints for the back flow and inhalation through design optimization.

Cited by 0 works.

Authors