In this paper, a daylight system for large space such as factory roof, exhibition spaces, warehouses is introduced in terms of the application. These days the big type of daylight system is totally imported and constructed on site, but some families of the small type system has been developed in domestic market. This research introduces the domestic and international technical trends and the localization of the big type system with the performance evaluation and the results analyzed. The performance evaluation include system efficiency, average indoor illumination and heat transmission coefficient. The system efficiency of developed product was measured 40.26% and the average illumination was 1,070lx at darkroom. That performance evaluation results are expected to be applicable in a large space. The heat transmission coefficient of the system was measured 2.0W/㎡K. That meets the criteria of 'Heat Transmission Coefficient of Local Building Window and Door' for central region. So the localized product can be applied across the country.