천공형태별 광파이프 시스템에 의한 실내 조도 평가

신화영, 박훈, 이종수 et al. · 한국생태환경건축학회 학술발표대회 논문집 · 2008

Among various daylighting systems, lightpipe system which is being increased actively and applied in buildings due to simple, cheap and easily constructed . However, It is required data of daylighting performance evaluation of light pipe considering variation. This study aims to comparative effect of diffuser in light pipe on daylight performance by Mock-up experiment. The light pipe produced by the S Inc. and it has a length of 1.3m and a diameter of 650mm. The experimental model is Mock-up which is 4m×4m with a height of 6m. The walls and ceiling are finished sandwich panels and the floor is finished astile. A light pipe has been mounted on the roof of the windowless mock-up model. All sensors used for interior and exterior illuminance measurements were monitored using 51 calibrated Li-Cor photometers. The mean value of interior illuminance was obtained by measuring every second from 09:00 to 18:00 under clear sky and overcast sky conditions. For analysis indoor daylight environment floor illuminance and its illuminance distribution were discussed

Cited by 0 works.

Authors