질량분석기를 이용한 소변검체의 직접 동정
박강균, 신상현, 장지영 et al. · 임상미생물검사학회 초록집 · 2014
Objectives: We evaluated the performances and technical practicability of the Vitek MS MALDI-TOF system (bioMerieux) in identifying the urinary tract pathogens directly from urine specimens, since it can significantly shorten the time required for bacterial identification and will help in choosing the appropriate antibiotics. Methods: Urine specimens submitted to the microbiology laboratory between July and September 2013 for Gram stain and bacterial culture were included in this study. Bacterial identification was performed with conventional method using Vitek 2 system. For urine samples showing single morphotype on Gram stain were processed both by culture and MALDI-TOF. For MALDI-TOF analysis, urine (3 ml) was centrifuged at 2,000 g for 30 s to remove leukocytes. The supernatant was centrifuged at 14,100 g for 10 min to collect bacteria. The pellet was washed once with deionized water. To the pellet, 1.5 ml of basic solution was added and incubated at 37℃ for 10 min. After centrifugation at 14,100 g for 10 min, it was washed twice with DW and after removal of supernatant, the pellet (8-10 ul) was applied to the MALDI plate in duplicate and were dried on a slide warmer (56℃) for 10 min. Then, 1 ul of matrix solution was added to each well. For cases of yeasts, formic acid (product no. 411072, bioMerieux) was applied before the addition of matrix solution. Results: Of the 2,370 urine specimens submitted to the microbiology laboratory, 251 samples showed single morphotype on Gram stain and among them 202 urine specimens were available for MALDI-TOF (Table 1). Of the 202 specimens, growth of colonies were observed in 189 samples and 145 samples led to significant growth of one colony morphology in culture. One-hundred and ten (75.9%) of them with colony counts of >=10 5 CFU/ml. They were 71 enteric GNB, 5 glucose-non-fermenting GNB, 9 GPC, and 25 yeasts and 70 (98.6%), 3 (60.0%), 4 (44.4%), and 5 (20.0%) isolates of them were correctly identified by MALDI-TOF, respectively. Thirty-one (21.4%, 11 GNB, 7GPC, 12 yeasts and one GPB) of them led to colony counts between 104 and 105 CFU/ml, and among them, 7 GNB, 1 GPC and 1 yeast was correctly identified. Four (2.8%) samples gave colony counts between 103 and 104 CFU/ml and none of them were correctly identified. Thirteen samples were negative in culture and MALDI-TOF did not find any significant protein profile in any of these cases. Conclusion: For enteric Gram-negative bacilli, which is the major urinary tract pathogen, Vitek MALDI-TOF MS was excellent in identifying when it was present in > =10 5 CFU/ml and also good when it was present in between 10 4 and 10 5 CFU/ml. However, improvement is needed for GPC and yeasts.
Cited by 0 works.