다중 상호작용을 고려한 유체탱크의 효과적인 동수해석

Nam Kyu Kim, 서춘교, 이종재 · 한국지진공학회 춘계학술발표회 논문집 · 2012

The recent explosion of nuclear power plant (NPP) in Japan was mainly due to performance malfunction in cooling system caused by an earthquake. Thus, seismic analysis has been of great important for auxiliary feed water (AFW) tank, one of the cooling systems in NPP. The existing seismic analysis of the AFW tank is based on the entire aux stick finite element model (FEModel) with AFW tank, which leads to a conservative result. In this research, two types of fluid tank analysis methods, static analysis including the effect of dynamic pressure and frequency domain analysis accounting for both dynamic mass and spring, have been proposed using the substructure method for an AFW tank. The proposed analysis method accounted for multi-physical interactions and needed only FEModel of the AFW tank for effective substructure method. Compared to those of existing conventional analysis packages, the results of the proposed analysis methods show an effective solution for seismic analysis of fluid storage tanks in NPP.

Cited by 0 works.

Authors