Objective To investigate mechanical properties of the thoracic spine fixed with pedicle screws that were placed using a ”funnel technique”. Method Fourteen thoracic spinal segments (T6 to T10) were collected from adult cadavers. These specimens were divided into two groups, 7 in each, and fixed with pedicle screw using funnel and Magerl techniques. The displacement stiffness of the spinal segment and the pull-out strength of the pedicle screw were tested for intact and fixed spinal specimens. The displacement stiffness was measured from different loading directions, including axial compression, anterior flexion, posterior extension, lateral bending and axial torsion. Results Compared to the intact spine segments, the displacement stiffness is significantly increased (P<0.05) at all directions in the segments fixed with either funnel or Magerl technique; however, there is no significant difference between the groups fixed with different technique. The screw pull-out strength is significantly decreased (P<0.05) in spine segments fixed with Funnel technique compared to those fixed with Magerl technique. Conclusions Since funnel technique removed a portion of bone from the posterior side of the vertebral pedicle, it can raise the accuracy and safety for the placement of pedicle screw. Although this technique does not affect the stiffness of fixed spinal segment, it may decrease the anchor strength of pedicle screw. Accordingly, we recommend that the funnel technique can be considered as a complement method for the fixation of vertebral fracture using pedicle screws.