토크전단형 고력볼트의 토크계수와 온도변수에 관한 회귀분석

나환선, 김우범 · 한국강구조학회 학술발표대회 논문집 · 2015

The torque shear high strength bolt is generally clamped when the pin-tail of bolt shank is broken. Sometimes the clamping forces on slip critical connections do not meet the required tension due to ambient conditions such as outdoor temperature, moisture and dust. This is why torque coefficient is affected by lubricant coated on bolt. From this study, the clamping forces of torque shear bolts at indoor conditions are compared with actual data investigated from 24 construction sites last five years. Similarly to foreign literature results, torque shear bolts shows that torque coefficients are fluctuated greatly by temperature conditions. The range of torque coefficient at indoor conditions is analyzed from 0.126 to 0.158 while tensions are indicated from 179 to 192 N·m. Instead, the range of torque coefficient at site conditions is analyzed from 0.118 to 0.152. Based on this test, the variable trends of torque coefficient subjected temperature can be traced via statistic regressive analysis. In case of indoor conditions, it is showed that the variable of torque coefficient is 0.13% per 1℃, as the quantitative equation is taken : k= -0.0002·t + 0.1497. While the variable at actual site conditions reaches 2.73% per 1℃. the following equation is taken : k= -0.0042·t + 0.1539. Based on this analysis, the variation of torque coefficient reflected both indoor results and outdoor results is analyzed as 1.91% per 1℃.

Cited by 0 works.