ВЛИЯНИЕ РЕГЕНЕРАЦИИ ЭНЕРГИИ НА ЭФФЕКТИВНОСТЬ УТИЛИЗАЦИИ НИЗКОПОТЕНЦИАЛЬНОГО ТЕПЛА МЕТАЛЛОГИДРИДНОЙ УСТАНОВКОЙ НЕПРЕРЫВНОГО ДЕЙСТВИЯ

Михаил Романович Ткач, Б. Г. Тимошевский, Serhii Dotsenko et al. · The Scientific Issues of Ternopil Volodymyr Hnatiuk National Pedagogical University Series pedagogy · 2014

It is shown that the heat recovery efficiency for the low-speed ICE based on metal-hydride equipment of the continuous operation and energy recuperation can exceed 25%. Thermal energy recuperation has allowed to increase the efficiency of the installation on 14%, and mechanical energy on the engine crankshaft additionally on 3%, depending on desorption temperatures. It is defined the temperature gradients in the recuperation heat exchanger depending on the range of the recuperation and desorption temperature. It is proposed recommendations on the use of existing metal hydride materials. It is obtained that heat recovery efficiency is 25% if material ZrCrFe1,6 is used, and Рmax =15 MPa, Рmin= = 0.5 MPa ηРМР = 0.9 ηНР = 0,9, rt = 0,8 Тд = 450 K.