터널용 전기식 집진설비 현지시험(2)

태경응, 유경훈, 오명도 et al. · 대한설비공학회 학술발표대회논문집 · 1997

On-site test of ESP unit in road tunnel has been carried out to evaluate its adaptability to real situation. The selected tunnel was Nam-San No.3 tunnel in seoul. The tested were dust collection performance variation with time, size distribution of collected dust on plate and optimum water pressure for cleaning collection plate. The results showed that the initial collection efficiency is 86.6% and 7day-elapsed efficiency 81% for nominal 6m/s. The collected dust amount was 518g/cell and the size distribution covered from 0.14㎛ to 249㎛ with geometric mean size of 17.51㎛.