심근경색증 환자에서 간헐파도플러 심초음파 검사에 의한 심실확장기능에 관한 연구
조승연, 박승정, 백경권 et al. · The Korean Journal of Internal Medicine · 1988
Inflow characteristics of left and right ventricular filling were assessed in 33 patients with myocardial infarction and 20 normal subjects by pulsed doppler echocardiography. The presence of left and right ventricular diastolic functional change in accordance to the infarct location, serial change of left and right ventricular diastolic function in patients with acute myocardial infarction, and correlation between left ventricular end-diastolic pressure and pulsed doppler echocardiographic incices of left ventricular diastolic function were assessed. Patients with myocardial infarction were subdivided into two groups, the anterior infarct group(20 patients) and the inferior infarct group(13 patients), according to the site of the involved myocardium. Serial doppler echocardiograms were perfarmed three times, within 3 days after onset(lst phase), after about 12 days (2nd phase), and after 4 weeks (3rd phase). 1) Concerning the left ventricular diastolic function, A/E in the anterior infarct group(1.04±0.18) and inferior infarct group(1.07±0.23) was greater than in that of the control group(0.64+0.10)(p<0.05) The corrected isovolumic relaxation time in the anterior infarct group(2.34±0.60 √ms and inferior infarct group(2. 43±0.70 √ms) was longer than in that of the control (1.83±0.31 ms) (p<0.05). The 0.33 area fraction and E area fraction in the anterior infarct group(45±7%, 55±5%, respectively) and inferior infarct group(43+9 53±8%, respectively) were less than in those of the control group(59±9%, 67±5%, respectively) (p< 0.05, p<0.05, respectively) and A area fraction in the anterior infarct group (43±6%) and inferior infarct group(47±8%) was greater than that in the control group(36±7%) (p<0.05). 2) In the right ventricular side, A/E in anterior infarct group(0.86±0.23) and inferior infarct group(1.01±0.16) was greater than in that of contol group(0.62±0.10) (p<0.05), peak A velocity in inferior infarct group(0.44±0.09 m/s) was higher than in those of anterior infarct group(0.36±0.10 m/s) and control group(0,28±0.05 m/s) (p<0.05), 0.33 area fraction and E area fraction in anterior infarct group(43±7%, 52±10%, respectively) and inferior infarct group(42±9%, 50±10%, repectively) were lesser than in those of control group(56±9%, 63±7%) (p<0.05, p<0.05, respectively), and A area fraction in anterior infarct group(48±10%) and inferior infarct group(49±9%) was greater than in that of control group(36±7%) (p<0.05). 3) Serial left ventricular pulsed doppler echocardiogram in 12 patients with acute myocardial infarction showed follwoing results. A/E in phaae 2(0,86±0,17) and phase 3(0.83±0.21) was lesser than in that of phase 1(1.07±0.22) (p<0,05), 0,33 area fraction and E area fraction in phase 2(53±10%, 59±8%, respectively) and phase 3(55±9%, 59±7%, respectively) were greater than in those of phase 1(43±8%, 49±9 respectively) (p<0,05, p<0,05, respectively), A area fraction in phase 2(39±8%) and phase 3(39±8%) was lesser than in phase 1(49±11%) (p<0,05), and these variables were not changed between phase 2 and phase 3. 4) Serial right ventricular pulsed doppler echocardiogram in 12 patients with acute myocardial infarction showed following results, A in phase 2 (0.35±0.10 m/s) and phase 3(0,31+0,06 m/s) was lower than in that of phase 1(0,46±0.09 m/s) (p<0.05), A/E in phase 2(0.92±0.26) and phase 3(0,78±0.18) was lesser than in that of phase 1(1.10±0.16) (p<0.05, p<0.01, respectively), 0,33 area fraction and E area fraction in phase 2(53±10%, 47±9%, respectively) and phase 3(53±8%, 42±9%, respectively) were greater than in those of phase 1(41±10%, 49±8%, respectively) (p<0.05, p<0.05, respectively), and A area fraction in phase 2(47±9%) and phase 3(42±9%) was lesser than in that of phase 1(50±7%) (p<0.05), 5) Left ventricular end diastolic pressure had a signi1icant high correlation with A/E (r=0,76, p=0.01), with 0.08 area fraction (r=0,71, p=0,02), and with E area fraction
Cited by 0 works.