뇌하수체 미세선종에서 역동적 자기공명영상의 유용성
Chang‐Soo Lee, 이은영, 주양구 et al. · KUMeL Repository (Keimyung University) · 1996
Purpose: To investigate the usefulness of dynamic MR imaging in the diagnosis of pituitary microadenomas. Materials and Methods: Dynamic MR imaging was performed in 31 patients with suspicious pituitary microadenoma. The MR examination was performed on a 2.0T or 1.5T superconductive MR unit using spin echo(SE) technique with arepetition time of 200msec, echo time of 15 msec, 128 ?256 matrix and one excitation. Actual sampling time perimage was 26 seconds. The field of view was 25cm and a section thickness of 3mm with 2mm gap was chosen. After arapid hand injection(2-3ml/sec) of Gd-DTPA(0.1 mmol/kg of body weight), dynamic coronal plane MR images wereobtained every 20-30 seconds for 3-5 minutes. Between never and ten serial images were usually obtained. Afterdynamic MR imaging, routine SE T1-weighted images(T1WI) were obtained in the same plane as dynamic images, anddetection rates of pituitary microadenoma using dynamic MR imaging and using routine enhanced T1WI, wereretrospectively compared. Results: On early dynamic images(30