양안시 조건에 따른 양안굴절검사 값의 변화
박상배, 정연홍, 김대현 et al. · 대한시과학회지 · 2006
The objective of this study was to determine whether and in which way the changes of sphero-cylindrical power and cylindrical axis deviation during binocular refraction after monocular refraction, especially in regard to the binocular visual condition of the ametropia patient. Most authors reported previously that binocular refraction will change the values of monocular refraction toward less minus spherical power and axis changes in most patient. One hundred fifteen patients varying in age from 7 to 60 were performed Humphriss immediate contrast(HIC) test with pantoscopic tilt angle after conventional monocular refraction. There was correlation between the distance deviation pattem and the cylindrical axis deviation(F = 3.296, p 二0.012). There was significant correlation between the spherical power(F = 1.627, p = 0.01이, cylindrical power(F = 1.739, p = 0.004) and cylindrical axis deviation change(F = 1.702, p = 0.005) and the accommodative convergence/accommodation(AC/ A) ratio in binocular refraction. But none of our patients was found to have correlation between the near point convergence and spherical power(F = 0.793, p = 0.667), cylindric허 power(F = 0.783, p = 0.677) and cylindrical axis deviation change(F = 1.448 p = 0.140) and NPC. The spherical power(t = -3.452, p = 0.001) and cylindrical power(t = -5.571, p = 0.000) decreased and the cylidrical axis changed to 5.73:!:8.00o in the patients having incyclo-deviation of cylindrical axis. The cylindrical power(t = -3.630, p = 0.000) decreased and the cylindrical axis changed to 5.38:!:5.360 in the patients having excyclo-deviation of cylindrical axis. But it was revealed that there was no change of sphero-cylindrical power in the patients having no change in cylindrical axis(t = -1.621, p 二0.113). The sphero-cylindrical power was changed by distance deviation pattem and AC/ A ratio. And there was significant difference in findings between the cylindrical axis deviation and distance deviation pattem of the patient. These results are in agreement with those of previous studies comparing sphero-cylindrical power and cylindrical axis deviation values between monocular refraction and binocular refraction. The findings in this study provide that the binocular visual condition of the ametropic patient may play a significant role in the sphero-cylindrical changes and cylindrical axis deviation in binocular refraction. Future studies will be required to ascertain the correlation between the cylindrical axis deviation and the distance deviation pattem.
Cited by 0 works.