철근 절곡형 전단보강근을 사용한 플랫 플레이트 슬래브의 전단보강
김준서, 최창식 · 대한건축학회 춘계 우수졸업논문전 수상논문 개요집 · 2009
The punching shear on the flat plate slab-column connection can bring about the reason of the brittle punching shear failure which may result of collapsing the whole structure. From the development of residential flat plate system, the shear reinforcement is developed to preventing the punching shear. This study proposed 3 reinforcements that are increased to bond capacity using lateral Bar. From the result of test, slab is failed before yield strength of shear element due to anchorage of slip because slab can not keep enough bond length. According to the test result, an effect of slab thickness and concrete compressive strength are analyzed by FEM. This study suggest shear strength formula that can more accurately calculate a positive shear reinforcement in slab-column connection.
Cited by 0 works.