축열식 히트펌프 시스템의 난방기간 실증운전 결과 및 운영비용 분석
김득원, 허재혁, 김민휘 et al. · 대한설비공학회 2018년도 하계학술발표대회 · 2018
The heat pump systems were installed for heating and cooling of public buildings in Jincheon Eco-friendly Energy town. Heat pump system was operated in night time to save the operational cost, and the hot heat was stored in the thermal energy storage(TES). In this study, the performance of heat pump systems(geothermal, sewage heat, residual heat of TES) with the TES during heating season were analyzed, and the operational cost was compared with and without the TES. The electric chiller model was used to simulate heat pump applied in without thermal energy storage system. Electric rates of each system was measured to calculate operational cost. When the TES used in the air-conditioning system, the electric load(35.5 MWh) calculated in day time can move to off-peak load time, and the total electric cost is saved by 16.1%.