복합집열기에서 핀-튜브 열교환부 배관 분지수에 따른 전열 성능에 관한 수치해석 연구
최휘웅, 파쿠르 로커만, 류남진 et al. · 한국태양에너지학회 추계학술발표회 논문집 · 2016
An hybrid soalr collector is made of flat plate solar collectors that have fin-and-tube heat exchanger as an outdoor unit for applying to the heat pump system. The heated water by solar irradiance, ambient air can be used as heat source for evaporator in heat pump system. Thus, C.O.P.(coefficient of performance) of the heat pump and thermal efficiency of the collector can be increased similar with traditional solar assisted heat pump system because of high evaporation temperature of the heat pump and low operating temperature of collector respectively. In this study, features related to heat transfer of hybrid solar collector were investigated according to a number of distributed tube row using the CFD(computational fluid dynamics) model. As a result, heat transfer was decreased with increment of a number of distributed tube row and pressure drop was also decreased similar with heat transfer rate. Thus, finding the optimal condition of a number of distributed tube row needs to be researched as further study.