Уровень мощности экспозиционной дозы гамма-излучения кабинетов информатики

Ж Ш Мадихан, Gulnur Urgushbaeva, К. М. Кибатаев et al. · 2019

Purpose: The goal of the study was to study the level of exposure dose rate (EDR) of gamma-radiation of informatics classrooms. Materials and methods: The study was conducted in 2 computer science classrooms, 2 classrooms and the corridor of the department of natural science disciplines, located on the 2nd floor of the 2nd academic building of the«NES ZKMUMarataOspanova». Measurements of the exposure dose rate (EDR) of gamma-radiation were carried out using the DRGB-01 “Eco-1” dosimeter, produced in 2009. The EDR level was determined in the center of computer science classrooms and at a distance of 0.5 m from the computer screen and at a height of 0.5 m and 1.0 m from the floor. In the classrooms and the corridor, in the center at a height of 0.5 m and 1.0 m from floor. At each point, at least 3 measurements were taken and the average value was determined. Results and discussion: The study showed that before the computers were turned on in the informatics classrooms, they also met the sanitary standard; after turning on the computer in Cabinet No. 211, the average EDR value at 0.5 m from the floor did not change, at 1.0 m increased from 0.09 μSv / h up to 0.11 μSv / h (by 22.2%). In the office №222, after turning on the computer at a height of 1.0 m, the EDR increased from 0.10 μSv / h to 0.11 μSv / h (by 10%). Conclusions: Thus, with the computers turned on, the levels of gamma-radiation EDR at a height of 1.0 m from the floor (user level) increased to 22.2%, but they did not exceed the maximum permissible levels.