Определение энергоэффективности установки первичной переработки нефти

М. В. Канищев, Valery P. Meshalkin, Л. М. Ульев · CyberLeninK (CyberLeninka) · 2019

The method of comparative analysis for oil refineries energy efficiency is proposed in this paper. The method is presented on the example of a crude oil unit operation analysis with a nominal capacity of 7 million tons per year for the crude oil. To quantify energy efficiency, an index of energy efficiency potential is introduced, which is defined as the ratio of the difference between the useful loads for the hot utilities of the existing and standard units to the useful load of the existing unit hot utilities. The current unit with a heat exchange system, in which there is a minimum temperature difference between the heat carriers in the vertical heat exchange, equal to 10 °C is considered as a standard unit. Determination of the useful load of hot utilities is based on the rules of process integration, in particular, on the pinch analysis principles. For this purpose, instrumental measurements of the parameters for all process streams of the unit involved in heat exchange were performed. The obtained results, together with the CPL data, allowed us to build a stream table and a grid diagram for the existing recuperation system of unit, analysis of which showed the effect of heat losses to the environment on the change in flow enthalpy of process streams in the system of heat exchange. The estimation of the heat loss capacity from the heat exchange equipment of the installation is made. With the help of engineering modeling of the unit in the HYSYS environment, the refined and energy-balanced grid diagram and the stream table were synthesized. Using the refined data of the stream table, the composite curves of the unit process stream system were constructed, which determined the useful load for the hot utilities of the existing process with the nominal duty of the unit. When modeling an existing unit, the heat losses to the environment were not taken into account, then to estimate the current useful load on the hot utilities, the capacity of heat losses in the heat recuperation system was added to the load value found using composite curves. To determine the useful load of the standard unit, composite curves are plotted for a minimum temperature difference of 10 °C. The calculated index of the energy efficiency potential of the process s ef  is 0.37. This value is an absolute characteristic of the perfection for the process under consideration. The value of the energy efficiency potential index for a project of an economically optimal unit retrofit is determined: s  ef_opt = 0.35.

Cited by 0 works.

Authors