Влияние поляризационных характеристик пробного излучения на сигнал оптически детектируемого магнитного резонанса в магнитометрических и гироскопических квантовых датчиках

Anton K. Vershovskii, С.П. Дмитриев, Anatoly S. Pazgalev et al. · Письма в журнал технической физики · 2019

The influence of polarization characteristics of probe laser radiation in quantum sensors, i.e. magnetometers that use the electron paramagnetic resonance, and gyroscopes that use both the electron and nuclear magnetic resonances, on the amplitude of the magnetic resonance signal is considered. The relations between the magnitude of the magnetic resonance signal and the parameters of the elements of the optical scheme of the sensor are derived using the Stokes – Muller formalism and experimentally verified; It is shown that the main destructive effect on the signal in a standard two-beam scheme is exerted by phase delays introduced by both metal and dielectric mirrors. Methods for compensating for this destructive influence have been proposed and tested.

Cited by 0 works. doi:10.21883/pjtf.2019.20.48383.17930 Open-access PDF