회수온도 저감에 따른 열배관의 피로안전성 평가

박진은, 경갑수, 안용모 et al. · 한국강구조학회 학술발표대회 논문집 · 2010

One of main equipment of district heating systemis a heating pipe, which could be classified into supply and return pipes. District heating transmission pipe, which is charged with district heating in small tomedium-size cities, is occurred under thermal stress on temperature variance of heating water. According to the number of serviced years, fatigue phenomenon on the thermal stress is developed. Due to the increasing needs and the expanding supply of district heating, the heating demand has been increasing. In order to enlarge the heating supply of heating pipes which had been laid, separate measures are required. As one of the considerations, a thermal capacity security on the decrease of return temperature has been powerfully risen. In this study, field test was performed on a heating pipe which had been laid, and the data of each region was analyzed. And it was evaluated the fatigue of district heat pipes on the decrease of return temperature from cycle-based evaluation and stress-based evaluation.

Cited by 0 works.

Authors