항타강관말뚝과 현장타설말뚝의 주면마찰력 거동에 관한 현장실험 연구

정성민, 이민희, 송병덕 et al. · 한국지반공학회 춘계 학술대회 · 2005

In this study, static pile load tests for instrumented drilled shaft pile and instrumented driven steel pipe pile were performed. Based on the results of pile load test, skin friction of each stratum was compared. Skin friction of drilled shaft were more than those of driven pile at the same settlement. This was based on the difference of surface roughness of piles and pile construction methods.

Cited by 0 works.

Authors