Электропроводность и разность биопотенциалов тканей привитых компонентов ряда плодовых культур

Е. Е. Гужова, Самощенков Егор Григорьевич, Паничкин Леонид Александрович · Horticulture and viticulture · 2015

The results of the study of the electrical conductivity of tissue and the difference of bioelectric potentials of the polar parts of inoculations depending on the quality of accretion are presented. Objects of research are Sorbus L., Malus domestica P. Mill, Prunus domestica L., Prunus cerasifera Ehrh., Prunus spinosa, Prunus armeniaca L. Researches were conducted in the field and laboratory conditions. In the field conditions we researched electrical conductivity in the graft combinations and their correlation with the amount of growth. In laboratory conditions we observed inanition for normal grafts accretion when we took stocks without roots. There was educe correlation between conductivity and accretion quality of grafting. If there was the best grafting accretion so the conductivity value tissues of grafting components are monotony increased. The difference of biopotentials between apex and basal parts of grafted plant decreases by 30-40 mV (on the 14-th day after graft) in a good accretion.

Cited by 0 works. doi:10.31676/0235-2591-2015-6-40-46