МОДЕЛЮВАННЯ МЕХАНІЧНОГО НАВАНТАЖЕННЯ НА ЕНДОПРОТЕЗ НИЖНЬОЇ ЩЕЛЕПИ
Юрій Петрович Стасюк, Denis Chernogorskyi, Марина Юріївна Резнікова · Біомедична інженерія і технологія · 2019
The problem of optimizing the methods of endoprosthesis replacement of tender jaw today remains at the peak of relevance. Studying the biomechanics of implants makes it possible to determine the internal stresses and deformations, allows you to understand the mechanism of the disorder, as well as to choose the optimal treatment methods, to determine the functional prognosis of surgical interventions.The article presents the results of a full-scale experiment during which a test was carried out on the sagittal plane of the titanium endoprosthesis of the tender jaw. Got a deformation diagram of the blanks and calculated its rigidity. To determine the location of the maximum stress in the endoprosthesis, a mathematical simulation of the deformation of the blanks was performed, under conditions that repeat the experiment. Received the results of the calculation, which reflect the place with the maximum voltage that occurs in the endoprosthesis due to the action on it of the load.
Cited by 0 works. doi:10.20535/2617-8974.2019.2.184813 Open-access PDF
Authors
References
- Имитационное компьютерное моделирование напряженно-деформированного состояния нижней челюсти при проведении остеосинтеза и реконструктивно-восстановительных операций
- Визначення величини та особливостей розподілу сили прикусу при різних варіантах оклюзії з використанням вимірювальних плівок «Fuji Prescale» та системи «Тekscan»