지진으로 인한 화재 노출 후 내화피복재가 손상된 모멘트골조의 중력 기둥-보 접합부에 대한 열전달해석

장보라, Stephen P. Pessiki, 이은택 et al. · 한국강구조학회 학술발표대회 논문집 · 2012

This paper presents an analytical study on the heat transfer of steel moment-frame gravity beam-column connection with damaged Spray-applied fire-resistive material (SFRM) during in post-earthquake exposure. The gravity beam-column connection with damaged SFRM used in the analysis was predicted the effects of structural performance reduction when exposed to post-earthquake fire. The analysis in the study was performed heat transfer finite-element. The evaluated temperature in the connection caused by the fire was important part that reduced the strength and stiffness in the moment frame.

Cited by 0 works.