모세관 막힘 현상이 가정용 냉장고 시스템에 미치는 영향

유세열, 정지환 · 대한설비공학회 2018년도 하계학술발표대회 · 2018

The refrigeration cycle can cause the behavior of the entire component to change as one element changes, Because it behaves in conjunction with each component. Capillary tube are the most popular used as thermal expansion valves in compression type refrigeration system. The inside diameter of capillary tube is as small as 0.5 ~ 2.0mm. This leads to an efficient pressure drop, but it can cause clogging due to moisture or tiny piece of debris that have penetrated into the refrigeration system. In the present study, simulation technique are used to calculated the effects of capillary tube blockage phenomena on household refrigerators and the variation in the refrigeration cycle. Further, intend to effectively identify problems in the refrigeration system by transient analysis of blockage phenomena.

Cited by 0 works.