[연구논문-환경·플랜트] 마이크로웨이브를이용한슬러지건조시 발생되는폐가스처리
홍승모, 정연규 · 대우건설기술 · 2009
A bench-scale biofilter was used to demonstrate the treatability of off-gas containing odor and VOC which exited when reducing the sludge with microwave and hot wind sludge volume reducing system. With this operation factors in bench-scale, we installed and tested pilot plant scale reactor in wastewater treatment plant. Pilot plant biofilter was under operation in wastewater treatment plant packed with perlite and inoculated with activated sludge. Specially, this pilot plant system was operated continuously long-term in real treatment plant for studying biofilter performance over a 160 day period. Pilot plant biofilter achieved maximum removal efficiency more than 99% of odor and VOC. The results indicate that the biofilter medium with optimal moisture content and an effective bed retention time(EBRT) of 6.8sec could degrade 99% ordor and VOC at 10㎥/min loading rate.