인공태양을 이용한 이중외피 창호 시스템의 중공층 온도분포 실험 분석

조경주, 조동우 · 한국태양에너지학회 추계학술발표회 논문집 · 2018

Cooling energy reduction effects of double skin type window systems have been proven by several studies. However, the gap in the cavity between the layers of the double skin window system is approximately 1 m, which is too cumbersome to be managed by most residents. For this reason, overheated air in the cavity of the double skin window is not discharged often, which in turn leads to a failure of the double skin window system. Thus, an effective operation of the system can be achieved only if a double skin window system where residents can open or close the external and internal windows is applied and can be accessed at an arm's length. However, if the gap in the cavity is too narrow, it may degrade the air exhaust capability due to the insufficient flow of the internal air. As a result, this study experimented with the exhaust effect of the cavity in the slim type double skin window system and used a solar simulator as a light source. The experiments were conducted with regard to a total of three conditions: Case 1 was where the internal and external windows were all closed (90 degree of blind), Case 2 was where the external window was opened and the internal window was closed (90 degree of blind), and Case 3 was where the external window was closed and the internal window was opened (90 degree of blind). The comparison results of temperature distribution in the cavity when the external window was opened in the silm type double skin window system exhibited that the effective exhaust of warm air in the cavity can be achieved.

Cited by 0 works.

Authors