중저층건축물 관통형 필로티의 내풍설계를 위한 풍압계수 산정

우수현, 신동현, 류혜진 et al. · 한국풍공학회지 · 2019

Recently, the piloti is widely used for space utilization and cosmetic reasons. The piloti is located inside rather than the outer wall, but it is contact with the outside air. Therefore, when the strong winds are blown, a wind road is formed and under strong pressure, the ceiling of piloti or wall falls. In the present KBC-2016, the pressure coefficient of ceiling and wall for piloti is not presented. For this reason, the structural engineers have a difficulty in structural design for the main frame and cladding of the piloti. In this paper, the wind pressure coefficient was calculated by the wind pressure test for the penetration piloti of the low-rise building. The variables of the experimental model are the height and width of the piloti. The wind pressure coefficient is calculated according to the variables and the tendency of wind pressure distribution are compared and analyzed. Therefore, the most disadvantageous wind pressure coefficient among the variables of piloti is presented and it is provided as basic data for the main frame and cladding design.