공동주택 승강기 운행시 인접세대에서의 소음 및 진동 특성
이성찬, 정진연 · 대한설비공학회 2018년도 하계학술발표대회 · 2018
This study aimed to evaluation the noise and vibration with elevator operation in apartment houses. The main flat shape of the apartment house is supplied in the form of an overhead type rather than a corridor plan type. When the elevator hall and the main building are adjacent to each other, many complaints are generated. In this study, the noise and vibration characteristics during the elevator operation were evaluated. As a result of measurement of vibration and noise level in the inside of the elevator passageway, the maximum vibration acceleration levels at the floor and side walls were 51.5 dB and 42.5 dB, respectively, and the maximum noise level in the room was 35.9 dB(A) . The noise level of 40dB (A), which is the design standard of apartment house, was found to be acceptable. However, the noise level of 10dB(A) was more than 10dB(A).
Cited by 0 works.