거리조절 가능한 두부 수신 코일의 유용성 평가
강인한, 이호범, 장지성 et al. · 2019
Purpose:When inspecting MRI, A variety of efficient receiving coils are being developed as the importance of collecting high signal intensity by receiving coils gradually increases. This means that the receiving coil is made light and flexible, or that distance between the receiving coil and the human surface can be adjusted. Therefore, it is possible to collect high signals by keeping as close as possible to the examination areas of patients of various sizes of shapes. Thus, the purpose of this study was to compare the signal intensity with the distance between the receiving coil and the phantom by adjusting the distance control developed in consideration of the various patients and to find the actual clinical efficiency compared to the existing coil. Materials and Methods:In order to measure the signal intensity according to the distance variation between the receiving coil and the surface of inspection area, two cylindrical fluid phantom with same component and only different size were used. And the phantom images were acquired by increasing the distance between the receiving coil and the phantoms by 1cm from 0cm to 3cm. At this point, the ARC acceleration factor was applied up to 1-3 for each distance to measure the change in signal intensity according to the application of PI technique when the distance of the receiving coil and inspection area is varied. Standard T1 and T2 images were obtained using a 3.0T MRI and 48-channel head coil. Using acquired images, signal and noise data were obtained using subtraction methods according to the NEMA specification. And signal intensity of images was measured using the image evaluation program(Image J). The measured signal intensity was evaluated by comparing the variation in signal intensity with using one-way ANOVA and Duncan’s post hoc. Results:As a result, both in large and small phantoms, The closer the distance, the lower the AF of the PI technique, the greater the SNR and the farther the distance, the higher the AF, the lower the SNR in All phantoms. According to the ANOVA and Duncan’s post hoc test, there were no significant difference at 0cm, AF 1 which meant they showed almost identical signal intensities(p<0.05) in Large phantom but In Small phantoms, all groups had statistically significant differences from the maximum SNR. Conclusion:When using distance-controlled head-only coils, there was no statistical difference in the strength of the SNR when the distance was not increased within a certain distance without the use of PI techniques. Therefore, it is believed that MRI images with high quality SNRs can be obtained if the patient's physique is large or if the distance needs to be increased due to the use of medical devices.
Cited by 0 works.