폐기물 종류별 생태독성 평가를 통한 재활용유해성 검토

Min Joung Kim, 윤철우, 정미정 et al. · 2020

The Environmental Assessment of Recycling (EAoR) system protects humans and the environment from the pollution that results from recycling. Under the EAoR system, the Eco-Toxicity test applies to land-based (e.g., filling material) recycling larger than 120,000 tons or 30,000 m2 for recycling plants as defined by current laws (for new recycling methods currently undefined, the eco-toxicity test should always be applied regardless of size and weight). The eco-toxicity limit is less than TU 2.0 on the acute toxicity test by Daphnia magna. This study used the up-flow percolation method to get liquid samples from solid wastes for testing. We also analyzed heavy metals and other factors to evaluate their recyclability. Our results showed that 3 out of 5 waste types exceeded the toxicity limit. The maximum toxicity value was TU 44.4 in the incinerator. Heavy metal analysis proved that the content of Cr6+ in the waste exceeded the standard; hence, it can be highly toxic.

Cited by 0 works.