강제환기식 비육돈사 내 암모니아 발생특성
Gwanggon Jo, 장유나, 하태환 et al. · Journal of Agriculture & Life Science · 2020
Emission factors were determined by monitoring the ammonia concentration and ventilation rate of finishing pigs for 48 days in three pig rooms (i.e., rooms A, B, and C), all of which have the same structure and breeding environment. The experimental results show that the average ammonia concentration was 5.93 ppm, the ventilation rate was 23.7 m3/h·pig in the environment of the temperature was 22.5℃, and the humidity was 53.9%. The data correlation analysis on a daily basis showed that the ammonia concentration had a negative correlation with temperature (R2=-0.65 to -0.53) and the ventilation rate had a minimal effect on the ammonia concentration. The ammonia concentration gradually increased during the early hours in the morning and then reached a maximum value at midday (around 12:00–13:00). It was observed that the temperature, humidity, and ventilation rate with high cross-correlation data were maximum at 14:00–15:00. Based on the correlation analysis of the hourly data, factors that influenced the ammonia emission were the ammonia concentration (R2=0.71) and ventilation rate (R2=0.61), of which the ammonia concentration was more correlated. The ammonia emission factor was analyzed at 2.28 g/d·pig.