Електромагнітна сумісність перетворювачів підвищеної частоти електрорухомого складу з системи залізничної автоматики дільниць електрифікованих постійним струмом

А. М. Муха · The Scientific Issues of Ternopil Volodymyr Hnatiuk National Pedagogical University Series pedagogy · 2013

In article are presented results of the studies, with the help of simulation model, influences of the processes in traction converter of the raised frequency for asynchronous drive on systems of the automation electrified by direct currents area railways.Relevance. Influence on the reliability of the circuits of signaling, centralization, blocking (SCB) is expressed in the fact that the harmonics traction current is induced in the secondary coil of choke-transformers and entry their into the track relay at the imprecise tuning of protective filter may distort the code and signal overlap. Furthermore, the amplitude of these harmonics increases significantly at the current collecting due to the arc at the ice. At the same time the current may exceed significantly the permissible values. Thus, the theme of the work deals with the study of electromagnetic compatibility of high frequency converters of electric locomotive with the railway automation systems is an actual task.Results. Investigated high frequency converter in nominal mode, does not affect on the near body circuits of automation systems of d. c. electrified railways, because simulated values of the harmonics of input current amplitudes pulsating does not exceed the allowable values laid down existing regulations, safety in railway transport.

Cited by 0 works. doi:10.15802/ecsrt2013/51109