Аналіз методів визначення теплопровідності тонких плівок
M.O. Galushchak, Victor Ralchenko, Дмитро Михайлович Фреїк et al. · METHODS AND DEVICES OF QUALITY CONTROL · 2012
Absolute, 3ω- and flesh-method which used to thermal conductivity measure of thin films are presented. The chart and description of the method, given number of theoretical and empirical equations for thermal conductivity calculation. The absolute method for measuring thermal conductivity using the auxiliary conductive layer S-shaped form, which is heated with electric power. In the 3ω-method using alternating power of two different frequencies, which heats the metal heater-strip deposited on investigated thin film. According to the measured values of voltage and geometric dimensions and resistance of heater-strip determine the thermal conductivity of thin film structures. The laser flash-method is based on measuring the time heat waves created distribution laser pulse from one side of the film to the opposite. Using theory based on one-dimensional model of heat distribution in half-limited body, provided relatively little heat, you can determine the thermal conductivity of the investigated sample.
Cited by 0 works. Open-access PDF