Дослідження роботи асинхронних тягових двигунів при живленні від контактної мережі постійного струму

А. М. Муха · The Scientific Issues of Ternopil Volodymyr Hnatiuk National Pedagogical University Series pedagogy · 2012

Unified structure of the converter on the basis of high frequency transformers is proposed by author, which provides the ability to work of multi-system locomotive at the various parameters of contact net and various types of traction motors. The converter includes several functional units of energy conversion, which requires maximizing the energy conversion efficiency (ECE) for each of them to provide a high ECE in general.Purpose of work is to carry out studies to determine the energy conversion efficiency of the high frequency converter of multisystem locomotive with asynchronous traction motors (ATM), when powered by d. c. catenary.The results of determining the energy conversion efficiency of the converter of multi-system locomotive with asynchronous traction motors supplied from the d. c. catenary by voltage of 3 kV.The energy efficiency of a unified high frequency converter of electric traction power multisystem locomotive with asynchronous traction motors powered from the d. c. catenary was determined by the carried out investigation. Realization of the relatively high value of ECE in comparison with existing converters is implemented by using a high frequency transformer with a higher ECE, as opposed to the transformer of industrial frequency, and implementation of hybrid semiconductor switches that have a relatively low value of electrical losses.

Cited by 0 works. doi:10.15802/ecsrt2012/50657