О недостаточности оснащения паровых турбин приборами контроля для диагностики системы тепловых расширений
A. Yu. Sosnovskii, Б. Е. Мурманский, Ю. М. Бродов · Энергетик · 2018
The data analysis and generalization about the modern steam turbine units equipped by monitoring instruments are presented. The system includes automatic monitoring instruments for values of vibration and mechanical parameters. The diagnostics sufficiency for the complicated thermal expansions of bearing cases is considered. It is shown that the provided by manufacturers regular equipment of steam turbines doesn't correspond to requirements of up-to-date standards of the control amount for the thermal expansion system conditions. By complement of modern automatic monitoring systems for vibration and mechanical values most of the focus is on the vibration monitoring. The infringements in the thermal expansion system operating cause changes in the vibration condition of the turbine. The amount of the monitoring instruments purchasing for the detection of these infringements reasons is not enough in most cases. It is proved that the automatic monitoring instruments for values of vibration and mechanical parameters equipping to the necessary level will not increase the system cost by far. It is also shown that the digital registration of the thermal conditions parameters for the turbine elements should be organized when the steam turbines are equipped by modern automatic monitoring instruments for values of vibration and mechanical parameters systems.
Cited by 0 works.