ナトリウム-水反応ジェットコードの整備・解析

斎藤 義則, 糸岡 聡, 床井 博見 et al. · Institutional Repositories DataBase (IRDB) · 1998

In selecting the reasonable DBL on steam generator, it is necessary to develop analytical method for estimating the sodium temperature on failure propagation due to overheating. Using basic code for sodium-water reaction (SWR) jet, this work includes improvement of the analytical model, inspectional analyses for SWAT-3 experiments and practical analyses for Monju evaporator. The inspectional analyses were carried out for 2 cases of Run-19 \& 17 on the SWAT-3. Behavior of SWR jet on the results is reasonable. Moreover, suitable value for reaction rate coefficient was evaluated. The practical analyses were carried out for 5 different conditions on the evaporator. The effects of running conditions, Na pressure and flow rate on the jet behavior were estimated for the first time. Improvement of calculating efficiency on the basic code were considered. An implicit method with SIMPLE are most suitable for applicable development and reduction of calculating load.