조기강도 발현 저발열 콘크리트 특성
조일호, 성찬용 · 한국농공학회 학술대회초록집 · 2006
In this research, deals with the time dependence of fluidity and early strength of low heat mixed polycarboxylate based superplasticizer. It was measured through the curing early age 1 8~32hr and variation of slump flow and air content according to elapsed time. The test results was pump pressure of low heat concrete with slump of 22cm is higher than that of normal strength concrete with slump of 18cm by about 20~30%. The measured average 28days compressive strength of the concrete is 40MPa and the coefficient of variation is 2.3%. Also, it shows that viscosity and early strength can be increased by polycarboxirate. Heat of hydration was measured through various gages and analysis considering the steps of concrete placement were carried out.
Cited by 0 works.