고정도구 사용에 의한 경추부 자기공명영상의 움직임 인공물 개선 방안

이재흔, 박리사, 장재홍 et al. · 2014

Purpose : This study aims to suggest an additional examination method using an orally inserted guiding device in order to improve a motion artifact by involuntary oral motor such as removing one’s dentures and swallowing saliva in a clinically structured cervical spine MR scan. Materials and Methods : A C-Spine test was conducted with 13 patients who wore dentures among those who had a cervical spinal disease(Male: 7, Female: 6, Average age: 59±7.23) from December 1, 2013 through January 31, 2014. In selecting subjects, patients with claustrophobia and those who were taking a sedative medicine were excluded from the test. MRI scanner used in this study was 1.5T(Magnetom Avanto, Siemens, Germany) optimized for a cervical spine MR scan, and the cervical only phased-array neck matrix coil was used so as to obtain a high signal intensity. As experimental equipment, an orally inserted immobilization device(Endo-piece, Vision, Korea) was used. As for testing methods, first, the stability of the immobilization device and the information about the examination were described to the subjects; T₁-TSE-Sagittal, T₂-TSE Sagittal, T₁-TSE-axial and T₂-TSE-axial were obtained in a normal position and a supine position; a immobilization device was inserted in the patients’ mouth; and then T₁-TSE axial and T₂-TSE-axial were re-tested. For the evaluation and analysis of the images, a qualitative analysis based on the patients’ clinical findings and the results of reading and a quantitative analysis based on signal to noise ratio(SNR) and contrast to noise ratio(CNR) were used. Results : In SNR, T₁-TSE-axial before inserting the immobilization device was 22.33±8.59; T₁-TSE-axial after inserting the immobilization device was 25.21±7.93; T₂-TSE-axial before inserting the immobilization device was 14.49±5.74; and T₂-TSE-axial after inserting the immobilization device was 16.61±6.72. In CNR, T₁-TSE-axial was measured at 0.236±0.21 while T₂-TSE-axial at 0.219±0.22. As a result of the qualitative analysis, T₂-TSE-axial before using the immobilization device was 3.25±0.18 points while T₁-TSE-axial image after using the immobilization device was 3.95±0.14. Conclusion : The additional examination technique using an immobilization device was accompanied by minutes of delay and the patient’s fatigue, but the resolution and contrast of the images improved as the patients’ involuntary artifact decreased because of removing dentures and swallowing saliva, and it was found that the interpretation of the images and identification of the diseases improved as compared to the existing examination techniques. In particular, it was found that the blurry part of the boundary of the disease due to the motion artifact became clearer, and the quality of work improved.

Cited by 0 works.

Authors