비부착 표면매립 긴장보강된 철근 콘크리트 보의 거동 분석
정우태, 박종섭, 강재윤 et al. · 2020
Carbon fiber reinforced polymer (CFRP) strengthens concrete structures due to its corrosion resistance. Various structural strengthening methods have been developed and applied to strengthen deteriorated reinforced concrete structures, such as externally bonded reinforcements (EBRs) and near surface mounted (NSM) systems. However, both EBR and NSM reinforcement demonstrate premature failure. Recent research has attempted to prestress NSM reinforcement, but this requires a special prestressing system and various strengthening behaviors without filler. Therefore, this study develops a CFRP tendon and prestressing system for NSM reinforcement and investigates the strengthening effect considering the unbonded performance without filler and the damaged concrete. The test results reveal that the unbonding of the CFRP tendon improves the strengthening effect by 38%; however, it remains 17% less strong than the bonded specimen. The strengthening effect of the damaged concrete is similar to that of the general strengthened specimen. The use of a CFRP tendon with filler and anchorage system appears to improve stable strengthening behavior.
Cited by 0 works.