측정환경에 따른 센서 유형별 변형률 응답 비교를 위한 실험적 연구

박기태, 이규완, 한병원 et al. · 한국구조물진단유지관리공학회 학술발표회 논문집 · 2002

Until now electric resistive sensors are widely used in short term safety evaluation and long term monitoring system of bridge. These sensor type has good efficiency to short term measurement. However, in the case of long term measurement, the accuracy of measurment result is usually affected by electronic noise, humidity, ground earth, use of wireless telephone and length of lead wire and it can induce fluctuaton, drift, and spike of measurment signal. Because of these reason, vibrating wire sensor types are usually applied to long term monitoring system of bridges instead of electric resistive sensors, but vibrating wire sensor types also can not avoid the effect of various noise and length of lead wire. Therefore fiber optic sensor must be applied to measurement because of its various advantages in comparison with conventional sensor types. Nowadays fiber optic sensors are studied and developed as alternative proposal of conventional sensor types. In this study we executed the various laboratory test on examination of the fiber optic sensor's effect from electrical noise, time and temperature variation, and compared this result with measurement result from electric resistive sensors.

Cited by 0 works.

Authors