지연용해형 캡슐내 방사선 비투과 표지자를 이용한 대장분절 통과시간

최황, 최명규, 김병욱 et al. · Journal of Neurogastroenterology and Motility · 2000

Backgrounds/Aim: Scintigraphic measurement of colon transit has proven usefu1 clinically and in the research area, however this method requires well equipped laboratories. The aim of this study was to develop a new colon transit test using radiopapue markers instead of radiolabeled pellets in a methacrylate-coated capsule. Methods: Ten healthy volunteer. were studied. After simultaneous administration of two methacrylate-coated gelatin capsules containing activated ehareoa1 mixed with 8 mCi of (99m)Tc or a commercially used radiopaque marker, scintigraphies and plain abdominal X-rays were performed. We compared colon transit profiles as the geometric center at 4, 8, 24, and 48 hours after ingestian of gelatin capsules. This new radiopaque marker test was validated with a scintigraphic method as the gold standard. Results: Geometric centers (mean±SEM) of (99m)Tc-scintigraphy were 0.50±0.18 at 4 hours, l.l6±0.05 at 8 hours, 3.31±0.36 at 24 hours, and 4.16±0.29 at 48 hours. Geometric centers of the radiopaque marker method were 0.40±0,16, 1.13±0.05, 3.33±0.37, and 4.18±0.30 respectively. Transit profiles were the same with both methods and highly correlated (r=0.994, p<0.001). The difference between the two methods against the mean for the geometric center was within 2SD. Conclusions : A colon transit test using radiopaque markers in a methacrylate-coated, delayed release capsule was inexpensive, simple, and reliable. This new test could be applicable when a gamma camera is not available. (Korean Journal of Gastrointestinal Motility 2000;6:52-60)

Cited by 0 works.

Authors