코어공시체에 의한 콘크리트구조물의 압축강도 평가에 관한 문헌적 검토

한민철, 김기정, 백병훈 et al. · 한국구조물진단유지관리공학회 학술발표회 논문집 · 2004

This paper reviewed the method as to the core obtaining and interpreting compressive strength with each specification and investigated the results of core testing done by the authors. Compressive strength of core specimens exhibited a slight decrease compared with that of standard curing specimens by about 2%. Especially, the lower the region of compressive strength, the bigger the reduction gap of compressive strength between core and standard curing specimens. In 20~40MPa of compressive strength, strength compensation with 7~1.6% is needed and in 40~60MPa, 1.6~1.8% is needed. According to most criteria as to core test, it is stipulated that the suspect concrete is considered structurally adequate if the average strength of the three cores, exceeds 0.85f’c and no individual strength is less than 0.75f’c. This may be due to the condition of obtaining samples, procedure for curing.

Cited by 0 works.